22.Cooling System

1. Used for maintaining the mold temperature and a faster molding cycle.
2. Basic guideline:

  • h>2d(Min. 0.75”);
  • W>7/16”
  • P=3d~5d(35~60mm);
  • the Min. distance between e.j. pins and waterlines :1/4”;
  • Check for leaks with a pressure of 60 PSI;
  • Try to minimize the length of one cycle.

image002

3. Baffles

image004

image006

4. the blocking of W/L

4.1 Brass pressur plug(from DME or HASCO).

image008

4.2 pressure fit by brass

image010

4.3 pipe thread

image012

5. O-ring. Attempt to minimize the use of Oring in the mold design.

5.1 the preferred supplier: Parker and Hasco

image014

image016

image018

image020

image022

5.2 O-ring used for the rotation and axial movement

image024

image026

6. the pipe plug data.

image028

7.Cooling design example

image030

image032

image034

image036

image038

09-1 (3